The range at a glance
| Motor ratings | 2.2 · 3.7 · 5.5 · 7.5 · 11 · 15 · 18.5 · 22 · 30 · 37 kW |
|---|---|
| Mixer shaft speed | 280 rpm or 450 rpm (from a 4-pole, 1500 rpm motor at 50 Hz) |
| Drive | Gearbox, or single-stage V-belt drive |
| Impeller | Hydrofoil or propeller |
| Shaft seal | Single mechanical seal; double mechanical seal for oil & gas and FGD |
| Wetted parts | SS 304 or SS 316; duplex stainless steel option for FGD |
| Non-wetted parts | MS (mild steel); stainless steel for dairy service |
| Motor | Flameproof (FLP) for hazardous areas, or non-flameproof (NFLP) where the area allows |
| Supply basis | Engineered and made to order; price on request |
Gear drive or belt drive?
Gear drive
Motor → gearbox → coupling → shaft → impeller. Compact, enclosed and robust, and preferred for severe duty. Ratios of about 5.36:1 give 280 rpm, and 3.33:1 give 450 rpm. Gear drive is the only option for dairy, pulp and paper, and distillery service.
Single-stage belt drive
Motor pulley → V-belts → shaft pulley, with the full speed reduction in one stage and no jackshaft. Simple to maintain, and available for oil & gas, FGD, edible oil, water and biogas duties. Pulley sizes are checked for belt rating, guarding and bearing loads.
Configuration by industry
| Industry | Drive | Mechanical seal | Motor | Wetted parts | Non-wetted parts |
|---|---|---|---|---|---|
| Oil & Gas | Gear or single-stage belt | Single or double mechanical seal | FLP or NFLP* | SS 304 / SS 316 | MS |
| Power / FGD | Gear or single-stage belt | Single or double mechanical seal | FLP or NFLP* | SS 304 / SS 316, duplex option | MS |
| Food & Dairy | Gear drive only | Single mechanical seal | NFLP | SS 304 / SS 316 | SS |
| Edible Oil | Gear or single-stage belt | Single mechanical seal | FLP or NFLP* | SS 304 / SS 316 | MS |
| Paper & Pulp | Gear drive only | Single mechanical seal | FLP or NFLP* | SS 304 / SS 316 | MS |
| Water & Wastewater | Gear or single-stage belt | Single mechanical seal | NFLP | SS 304 / SS 316 | MS |
| Distillery | Gear drive only | Single mechanical seal | FLP or NFLP* | SS 304 / SS 316 | MS |
| CBG & Biogas | Gear or single-stage belt | Single mechanical seal | FLP or NFLP* | SS 304 / SS 316 | MS |
* FLP where the site's hazardous-area classification requires it; NFLP only where the area allows. Duplex for FGD is chosen against the actual corrosion and erosion conditions.
How a unit is selected
- Define the mixing objective: circulation, blending, temperature equalisation or solids suspension.
- Confirm tank dimensions, internals, liquid levels and the nozzle position.
- Establish the fluid properties: density, viscosity against temperature, and solids or fibre content.
- Select the impeller and estimate power for the duty, then choose the motor rating and shaft speed.
- Check the shaft, bearings, gearbox or belts, and seal against the loads on them.
- Check materials, seal type, nozzle loads and hazardous-area requirements.
- Issue a datasheet and GA drawing for your approval.